top of page
Eppendorf Biophotometer D30

Eppendorf Biophotometer D30

  • Measuremet Range 0 - 100 ppm
    Wavelength Range 325-1100 nm
    Optical System Double Beam
    Spectral Bandwidth 2 nm
    Mobility Portable
    Brand Eppendorf
    Model No / Item Code D30
    Wavelength Accuracy +- 0.5 nm
    Wavelength Repeatability +- 0.2 nm
    Photometric Accuracy +- 0.3% T
    List No. r

     

    Absorption measuring range 0A –3.0A (260nm)
    BSA concentration range 7.5 ng/µL – 45.45 µg/µL
    BSA concentration range (UV 280 nm) µCuvette G1.0 75 ng/µL – 45.45 µg/µL
    ±0.03 µg/µL at A = 0
    ±0.076 µg/µL at A = 1 (0.5 %)
    BSA concentration range (UV 280 nm) UVette 10 mm 7.5 ng/µL – 4.5 µg/µL
    ±0.003 µg/µL at A = 0
    ±0.007 µg/µL at A = 1 (0.5 %)
    BSA concentration range (UV 280 nm) UVette 2 mm 37.5 ng/µL – 22.5 µg/µL
    ±0.015 µg/µL at A = 0
    ±0.038 µg/µL at A = 1 (0.5 %)
       
    Measuring principle fluorescence
    Method memory >100 method programs
    Operator guidance language Spanish, Italian, French, English, German
    Power consumption Approx. 15W during operating step
    Approx. 5W with dimmed display
    Random error absorption ≤0.002 at A=0
    ≤0.005 (0.5?%) at A=1
    Random error fluorescence
    Random error wavelength ±1 nm
    Random temperature error
    Smallest step size 1 nm
    Spectral bandwidth ≤4 nm
    Systematic error absorption ±1 % (A = 1)
    Systematic error wavelength ≤0.5 nm
       
    Wavelengths 230, 260, 280, 320, 340, 405, 490, 562, 595, 600 nm
  • List number: - R

    unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified.

    meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer.

LOGO-removebg-preview (2).png
Отказ от ответственности   ЕСЛИ НЕ УКАЗАНО ИНОЕ, СОДЕРЖИМОЕ ЭТОГО «ВЕБ-САЙТА» ЯВЛЯЕТСЯ СОБСТВЕННОСТЬЮ ЕГО ВЛАДЕЛЬЦЕВ. ОДНАКО, ТОВАРНЫЕ ЗНАКИ, ЗНАКИ ОБСЛУЖИВАНИЯ И/ИЛИ ЛОГОТИПЫ [НАЗЫВАЕМЫЕ «ЗНАКИ»), СВЯЗАННЫЕ С ПРОДУКТАМИ, ПЕРЕЧИСЛЕННЫМИ НА ЭТОМ «ВЕБ-САЙТЕ», ЯВЛЯЮТСЯ СОБСТВЕННОСТЬЮ ИХ СООТВЕТСТВУЮЩИХ ВЛАДЕЛЬЦЕВ, И ЕСЛИ ОНИ ПОЯВЛЯЮТСЯ С ПЕРЕЧИСЛЕННЫМИ ПРОДУКТАМИ, ОН ИСПОЛЬЗУЕТСЯ ТОЛЬКО ДЛЯ ЦЕЛИ. ИДЕНТИФИКАЦИИ ЭТИХ ПРОДУКТОВ. МЫ НЕ ЗАЯВЛЯЕМ НА СВЯЗЬ С ВЛАДЕЛЬЦАМИ МАРКИ, ЕСЛИ ТАК НЕ УКАЗАНО ИНОЕ.
ЗНАЧЕНИЕ НОМЕРА В СПИСКЕ: - «R» ОЗНАЧАЕТ ВОССТАНОВЛЕННЫЙ, «PO» ОЗНАЧАЕТ Б/У, «U» ОЗНАЧАЕТ Б/У, «T» ОЗНАЧАЕТ ТОРГОВЛЮ, «M» ОЗНАЧАЕТ СОБСТВЕННОГО ПРОИЗВОДСТВА, «AD» ОЗНАЧАЕТ УПОЛНОМОЧЕННОГО ПРОДАВЦА ОРИГИНАЛЬНОГО ОБОРУДОВАНИЯ ПРОИЗВОДИТЕЛЯ.
Inorbvict Healthcare India Pvt. Ltd. является только трейдером, реселлером и восстановителем.
О
location-information_edited_edited.png

INORBVICT HEALTHCARE INDIA PVT. ООО Офис № 311, 3-й этаж, торговый центр Xion, возле внутреннего двора Marriott, Хинджавади, Пуна, Махараштра-411012

phone-outline_edited_edited.png
personal-info_edited_edited.png

Продажи и поддержка
+91 97663 07660

  • Twitter
  • Facebook
  • LinkedIn
СОЦИАЛЬНОЕ

E-mail -  info@inhpl.com    Call -  +91 9766307660    ISO 9001:2015 Certified

© 2023 Дизайн Inorbvict Vortex Corporation

bottom of page